Inverted Bucket Steam Traps Series B
Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment.
Inverted bucket traps rely on the density difference between steam and water to drain condensate as it forms. An inverted bucket floats in condensate that surrounds the bucket. As the bucket moves up and down in the condensate, a linkage connected to the bucket closes or opens a discharge valve trapping the condensate or allowing it to escape. Maximum system efficiency results from steam space being kept free of condensate.
Information:
- Hoffman Specialty General Catalog
- Hoffman Specialty Service Parts Catalog
- Hoffman Specialty Series B Inverted Bucket Steam Trap Intruction Manual
- Hoffman Specialty Series B0 Inverted Bucket Steam Trap Submittal Sheet
- Hoffman Specialty Series B1 3/4" Inverted Bucket Steam Trap Submittal Sheet
- Hoffman Specialty Series B2 3/4" Inverted Bucket Steam Trap Submittal Sheet
- Hoffman Specialty Series B3 1" Inverted Bucket Steam Trap Submittal Sheet
- Hoffman Specialty Series B4 1" Inverted Bucket Steam Trap Submittal Sheet
- Hoffman Specialty Series B4 1-1/4" Inverted Bucket Steam Trap Submittal Sheet
- Hoffman Specialty Series B4 1-1/2" Inverted Bucket Steam Trap Submittal Sheet
- Hoffman Specialty Series B6 Inverted Bucket Steam Trap Submittal Sheet
Operation of Bucket Traps:
The trap body must be manually primed at initial start-up. (Under low load or superheat conditions, the trap may also need to be primed.) Under operation, the trap body will remain full of condensate.
An inverted bucket floats in the condensate that surrounds the bucket itself. As the bucket moves up and down in the condensate, a linkage connected to the bucket closes or opens a discharge valve located at the top of the trap, trapping the condensate or allowing it to escape.
During start-up, air is vented through a bleed hole in the top of the bucket into the return line. When air or steam flows into the trap, it enters the underside of the bucket and collects in the top of the bucket. The contained air and steam cause the bucket to become buoyant and rise in the condensate causing the lever mechanism to close the discharge valve into its seat.
The bucket loses its buoyancy as the enclosed steam condenses due to radiation losses and steam escaping through the bucket vent hole. When this happens, the weight of the bucket will cause it to fall and pull the valve off its seat, and the cycle repeats.
An optional thermal vent installed in the bucket allows faster air venting during start-up.
Characteristics of Bucket Traps:
- Completely drains condensate at saturation temperature.
- Open bucket design will tolerate moderate water hammer.
- Normal failure mode is open.
- Sediment and dirt are kept in suspension until discharged with condensate.
- Only two moving parts, lever assembly and bucket, leads to reliable operation.
- Does not sub-cool condensate.
- Marginal air handling during start-up.
- Cycles fully open or closed, which can create noise.
- May lose prime during light loads and blow live steam.
- Requires manual priming to provide water seal.
- Does not withstand freezing temperatures.
Primary Applications for Bucket Traps:
Best for stable, steady load and pressure conditions.
- Process main drip traps for continuous operations.
- Where condensate is lifted or drains into wet return line.
- Heat exchangers without a modulating steam regulator.
- High pressure applications.
- Drum type roller dryers.
- Steam separators.
- Laundry equipment.
- Siphon or tilting kettles.
Features and Benefits:
- Stainless steel internal components withstand corrosion.
- Cast iron bodies for long, dependable life.
- Wide range of seat pressures available – up to 250 psig to fit a wide variety of applications.
- B0, B1, B2, B3, and B4 models:
- Removable covers for easy in-line service.
- Optional built-in strainer reduces number of piping connections.
- Optional built-in thermal vent for faster heating. (B1, B2, B3 and B4 models only).
If you have any questions please give us a call at 1-800-781-7405 or email us your request. Sales@NationalPumpSupply.com
- Product
- Qty in Cart
- Quantity
- Price
- Subtotal
-
404356 Hoffman B2075A-3 3/4" Inverted Bucket Steam Trap W/o Strainer
Hoffman
$448.95404356 Hoffman B2075A-3 3/4" Inverted Bucket Steam Trap W/o Strainer. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density difference...$448.95 -
404365 Hoffman B2180S-3 3/4" Inverted Bucket Steam Trap W/ Strainer
Hoffman
$484.95404365 Hoffman B2180S-3 3/4" Inverted Bucket Steam Trap W/ Strainer. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density difference...$484.95 -
404361 Hoffman B2125S-3 3/4" Inverted Bucket Steam Trap W/ Strainer
Hoffman
$499.95404361 Hoffman B2125S-3 3/4" Inverted Bucket Steam Trap W/ Strainer. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density difference...$499.95 -
404369 Hoffman B2250S-3 3/4" Inverted Bucket Steam Trap W/ Strainer
Hoffman
$484.95404369 Hoffman B2250S-3 3/4" Inverted Bucket Steam Trap W/ Strainer. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density difference...$484.95 -
404368 Hoffman B2250A-3 3/4" Inverted Bucket Steam Trap W/o Strainer
Hoffman
$464.95404368 Hoffman B2250A-3 3/4" Inverted Bucket Steam Trap W/o Strainer. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density difference...$464.95 -
404364 Hoffman B2180A-3 3/4" Inverted Bucket Steam Trap W/o Strainer
Hoffman
$464.95404364 Hoffman B2180A-3 3/4" Inverted Bucket Steam Trap W/o Strainer. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density difference...$464.95 -
404362 Hoffman B2125T-3 3/4" Inverted Bucket Steam Trap W/ Thermic Vent
Hoffman
$549.95404362 Hoffman B2125T-3 3/4" Inverted Bucket Steam Trap W/ Thermic Vent. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density...$549.95 -
404360 Hoffman B2125A-3 3/4" Inverted Bucket Steam Trap W/o Strainer
Hoffman
$474.95404360 Hoffman B2125A-3 3/4" Inverted Bucket Steam Trap W/o Strainer. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density difference...$474.95 -
404357 Hoffman B2075S-3 3/4" Inverted Bucket Steam Trap W/ Strainer
Hoffman
$474.85404357 Hoffman B2075S-3 3/4" Inverted Bucket Steam Trap W/ Strainer. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density difference...$474.85 -
404354 Hoffman B2030T-3 3/4" Inverted Bucket Steam Trap W/ Thermic Vent
Hoffman
$547.85404354 Hoffman B2030T-3 3/4" Inverted Bucket Steam Trap W/ Thermic Vent. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density...$547.85 -
404353 Hoffman B2030S-3 3/4" Inverted Bucket Steam Trap W/ Strainer
Hoffman
$474.95404353 Hoffman B2030S-3 3/4" Inverted Bucket Steam Trap W/ Strainer. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density difference...$474.95 -
404352 Hoffman B2030A-3 3/4" Inverted Bucket Steam Trap W/o Strainer
Hoffman
$444.85404352 Hoffman B2030A-3 3/4" Inverted Bucket Steam Trap W/o Strainer. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density difference...$444.85 -
404350 Hoffman B2015T-3 3/4" Inverted Bucket Steam Trap
Hoffman
$558.95404350 Hoffman B2015T-3 3/4" Inverted Bucket Steam Trap W/ Thermic Vent. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density...$558.95 -
404349 Hoffman B2015S-3 3/4" Inverted Bucket Steam Trap W/ Strainer
Hoffman
$474.95404349 Hoffman B2015S-3 3/4" Inverted Bucket Steam Trap W/ Strainer. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density difference...$474.95 -
404346 Hoffman B1250T-3 3/4" Inverted Bucket Steam Trap W/ Thermic Vent
Hoffman
$464.95404346 Hoffman B1250T-3 3/4" Inverted Bucket Steam Trap W/ Thermic Vent. Hoffman Series B Inverted Bucket Steam Traps for efficient condensate drainage of industrial process and HVAC equipment. Inverted bucket traps rely on the density...$464.95